Technical Specifications

Polyurethane Injected Modular Heating Panels

TECHNICAL CHARACTERISTICS
Insulation material Thickness
mm
Light between supports in meters
1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 m
PU 050 390 156 070 050 020 16 11 -- -- -- -- -- kg
PU 100 -- 357 200 122 079 63 37 27 20 15 11 -- kg
PU 150 -- 562 330 205 130 90 65 50 40 31 24 19 kg
Thermal insulation
Materials Comparison Chart. Shows the advantage of low thermal conductivity of Polyurethane Foam, compared to the big mass of material and thickness used in order to compensate it.
Thickness Material Type
50 mm Polyurethane Injected Panel
80 mm
Expanded Polystyrene Panels
90 mm Mineral Wool
100 mm Cork
130 mm Wood Chipboard Sheets
150 mm Fiberglass
200 mm Softwood
760 mm Cellular Concrete Blocks
1720 mm Solid Brick Masonry
Admissible Loads for Ceilings or PUT Roofs
Thickness
mm
k Weight Load
P=kgf/m²
Hyperstatic Isostatic
Kcal Watt kgs/m²
M2 h
°C
M2
°C
0.5/0.5 60 80 100 120 150 60 80 100 120 150
50 0.35 0.41 10.89 Luz 3.90 3.65 3.40 3.10 2.75 3.45 3.20 2.95 2.75 2.40
100 0.18 0.21
12.89 Luz 5.80 5.15 4.75 4.30 3.70 4.90 4.45
4.10 3.75 3.20
150 0.12 0.14 -- Luz 7.30 6.50 6.00 5.40 4.75 6.20 5.10 5.10 4.60 3.95
Thermal Conductivity
Values for thermal insulation of sandwich panels with flat metallic Coating and polyurethane core PUR (l=0,025 W/m K)
d 1/α 1/^ ^ 1/αa 1/U U
mm m² K/W m² K/W m² K/W m² K/W m² K/W m² K/W
50 0,13 2,000 0,5000 0,04 2,170 0,461
100 0,13 4,000
0,2500 0,04 4,170 0,240
150 0,13 6,000 0,1667 0,04 6,170 0,162

Qualities

  • Do not damage the ozone layer
    Safe for people and the environment. Does not contain CFC´s.
  • High Temperature Insulation
    Wide thermal rage. Used for isolation of maximum temperatures up to 90°
  • Thermal insulation for low temperatures
    Under low temperatures, used to isolate up to -150ºC. With the peculiarity that its insulating capacity increases proportionally to the decreasing Operating Temperature.
  • Prevention of Water Seepage
    Reduce significantly the damage possibility caused by water and moisture filtration, due to the kind of joint between panels.
  • Quality remains unchanged over time
    Minimizes maintenance costs.
  • Do Not Spread Fire
    Presents an excellent fire behavior due to its limited flame spread and its low fire load. (EPS core has 98% of air).