Technical Specifications

Polystyrene Modular Thermal Panels

Thermal Transmittance (K) depending on thickness.
(For an EPS core of 15/kg/m³)
Thickness
(mm)
Thermal Transmittance (R)
W/m² K kcal/h.m² °C
50 0,741 0,637
75 0,529 0,455
100
0,370 0,318
125 0,308 0,265
150 0,265 0,227
200 0,185 0,159
Thermal resistance(R) depending on thickness.
Thickness
(mm)
Thermal Transmittance (R)
m² °K/W h.m² °C/kcal
50 1,35 1,57
75 1,89 2,20
100
2,70 3,14
125 3,24 3,77
150 3,78 4,40
200 5,41 6,29
Panel specification
Usable Width W.P.H.- 1220 m/m
W.P.- 1170 m/m
R.P.- 1145 m/m
Length To 20mts.
(as needed)
Thickness From 50 m/m
to 300 mm
Distance between supports of self-supporting panels depending on thickness and maximum load in kg/m². ForL/240deflection. With sheet metal cover.
PANEL
THICKNESS
mm.
PANEL
WEIGHT
kg/m²
MAXIMUM DISTANCE BETWEEN SUPPORTS IN METERS.
1 2 3 4 5 6 7 8 9 10 11 12
50 10.00 333 137 71 40 24 16 10 ---- ---- ---- ---- ----
75 10,35 471 203 105 59 36 24 17 14 10 ---- ---- ----
100 10.89
  308 159 89 57 39 29 22 17 14 11 ----
125 11.25   395 190 107 68 47 34 26 20 16 13 11
150 11.60   465 222 125 80 55 40 31 24 19 16 13
200 12.69   ----- 317 178 114 79 58 44 35 28 23 19

Qualities

  • Do not damage the ozone layer
    Safe for people and the environment. Does not contain CFC´s.
  • High Temperature Insulation
    Wide thermal rage. Used for isolation of maximum temperatures up to 90°
  • Thermal insulation for low temperatures
    Under low temperatures, used to isolate up to -150ºC. With the peculiarity that its insulating capacity increases proportionally to the decreasing Operating Temperature.
  • Prevention of Water Seepage
    Reduce significantly the damage possibility caused by water and moisture filtration, due to the kind of joint between panels.
  • Quality remains unchanged over time
    Minimizes maintenance costs.
  • Do Not Spread Fire
    Presents an excellent fire behavior due to its limited flame spread and its low fire load. (EPS core has 98% of air).